Alat Fetal Simulator Dengan LCD Nextion

Achmad Labibul Umam, Imam Tri Harsoyo, Aggiat Winner, Wahyu Arief Purnomo

Abstract


Abstract:  A Fetal Simulator is an instrument used to simulate calibrated heartbeats (BPM) to prepare a Fetal Doppler for operation. This study aims to design a fetal simulator prototype equipped with a more interactive Nextion LCD, which facilitates users in setting and monitoring the device’s operating parameters in real-time, as well as to conduct functional and comparative testing of the developed device. The research employs an experimental method with a design and development approach, focusing on the construction and refinement of the fetal simulator device. Functional testing results showed error rates of 5.4% at TP1 (battery input), 1.6% at TP2 (Nextion LCD input), 0.2% at TP3 (charger output), and 1.4% at TP4 (step-up output). Meanwhile, comparative testing using the Bistos BT-250 fetal Doppler demonstrated that the prototype successfully generated signals that were well detected by the reference device, within a BPM range of 30–240 as configured.

Abstrak: Fetal Simulator adalah sebuah instrumen yang digunakan untuk mensimulasikan denyut jantung terkalibrasi (BPM) sehingga dapat mempersiapkan Fetal Doppler  untuk beroperasi. Penelitian ini bertujuan untuk merancang prototipe fetal simulator yang dilengkapi dengan LCD Nextion yang lebih interaktif dan memudahkan pengguna dalam mengatur serta memantau parameter kerja alat secara real-time. serta melakukan uji fungsi dan uji banding terhadap alat yang dikembangkan. Metode yang digunakan adalah penelitian eksperimental dengan pendekatan rancang bangun, yang berfokus pada perancangan dan pengembangan alat fetal simulator. Hasil uji fungsi menunjukkan tingkat kesalahan masing-masing pada TP1 (input baterai) sebesar 5,4%, TP2 (input LCD Nextion) sebesar 1,6%, TP3 (output charger) sebesar 0,2%, dan TP4 (output step up) sebesar 1,4%. Sementara itu, hasil uji banding dengan alat fetal doppler Bistos BT-250 menunjukkan bahwa prototipe mampu menghasilkan sinyal yang terdeteksi dengan baik oleh alat pembanding, dengan rentang BPM antara 30–240 sesuai dengan pengaturan yang ditentukan.


Keywords


Fetal Simulator; Speaker; LCD Nextion; Minyak Trafo; Fetal Doppler

Full Text:

PDF

References


Arif Fernanda. (2023). Fetal Doppler Simulator Berbasis Arduino Uno (pp. 14–97). https://eprints.uwhs.ac.id/2047/

Arini, A., & Nurasmi, N. (2024). Pemantauan DJJ dengan Bantuan Dopler pada Ibu Hamil Ny.“H” umur 22 tahun G1P0A0 Sejak Usia Kehamilan 31 minggu 4 Hari Secara Komprehensif. Indonesia Berdaya.

Bustamante, S., Manana, M., Arroyo, A., Castro, P., Laso, A., & Martinez, R. (2019). Dissolved gas analysis equipment for online monitoring of transformer oil: A review. Sensors (Switzerland), 19(19), 4–12. https://doi.org/10.3390/s19194057

Fajrin, H. R., Maharani, S., & Fitriyah, A. (2021). Simulator Fetal Doppler. Medika Teknika : Jurnal Teknik Elektromedik Indonesia, 2(2). https://doi.org/10.18196/mt.v2i2.11212

Gaspar, J., Fontul, M., Henriques, E., & Silva, A. (2019). Push button design requirements and relations to button architecture elements. International Journal of Industrial Ergonomics, 70(February), 92–106. https://doi.org/10.1016/j.ergon.2019.01.001

Ghosh, A. K., Burniston, S. F., Krentzel, D., Roy, A., Sheikh, A. S., Siddiq, T., Trinh, P. M. P., Velazquez, M. M., Vielle, H. T., Nowlan, N. C., & Vaidyanathan, R. (2020). A novel fetal movement simulator for the performance evaluation of vibration sensors for wearable fetal movement monitors. Sensors (Switzerland), 20(21), 1–22. https://doi.org/10.3390/s20216020

Isnaeni, N., Amelia, S. K., Ichzan, M., Jumardin, Nurrahmi, S., Agus, J., Isradianti, D. F., & Bariah, K. (2024). Uji Kesesuaian Kinerja dan Analisis Reproduksibilitas Akurasi Tegangan Tabung Pesawat Sinar-X di Balai Pengamanan Alat Fasilitas Kesehatan Makassar. JFT: Jurnal Fisika Dan Terapannya, 11(1), 31–42. https://doi.org/10.24252/jft.v11i1.47855

Kurniawan, P. (2012). Rancang Bangun Fetal Doppler Dengan Tampilan LCD. Universitas Islam Indonesia Yogyakarta.

Kusnaidi, M., Yuliza, Y., & Ihsanto, E. (2020). Analisa Fetal Simulator yang Dilengkapi dengan Thermohygrometer. Jurnal Teknologi Elektro, 10(3), 176. https://doi.org/10.22441/jte.v10i3.005

Meler, E., Martínez, J., Boada, D., Mazarico, E., & Figueras, F. (2021). Doppler studies of placental function. Placenta, 108(March), 91–96. https://doi.org/10.1016/j.placenta.2021.03.014

Mohd Hanifa, R., Isa, K., & Mohamad, S. (2021). A review on speaker recognition: Technology and challenges. Computers and Electrical Engineering, 90(April 2020), 107005. https://doi.org/10.1016/j.compeleceng.2021.107005

Muhammad Nur, I., & Gunadi, I. (2019). Pemprograman Mesin Bor Otomatis Berbasis Atmega 328. 22(4).

Nadhirotussolikah, A., Pudji, A., & Mak’ruf, M. R. (2020). Fetal Doppler Simulator Based on Arduino. Journal of Electronics, Electromedical Engineering, and Medical Informatics, 2(1), 28–32. https://doi.org/10.35882/jeeemi.v2i1.6

Ningtias, D. R., Harsoyo, I. T., & Aulia, A. (2021). Pengaruh Duty Cycle terhadap Nilai Heart Rate pada Pengujian Alat Fetal Simulator Berbasis Arduino. Jurnal Fisika, 11(1), 27–36. https://doi.org/10.15294/jf.v11i1.29378

Nurahmadan, I. F., Agusta, A., Winarno, P. A., Sazali, B. H., Thurfah, Y., & Rosaliah, A. (2021). Perbandingan Algoritma Machine Learning Untuk Klasifikasi Denyut Jantung Janin. Seminar Nasional Mahasiswa Ilmu Komputer Dan Aplikasinya(SENAMIKA), 02(1), 733–740.

Tarzamni, H., Kolahian, P., & Sabahi, M. (2021). High Step-Up DC–DC Converter With Efficient Inductive Utilization. IEEE Transactions on Industrial Electronics, 68(5), 3831–3839. https://doi.org/10.1109/TIE.2020.2987253

Tri Harsoyo, I., Ulin Nuha ABA, M., Wahyudi, B., & Aji Firmansyach, D. (2024). Hotplate Magnetic Stirrer Dilengkapi Pengatur Waktu, Suhu dan Kecepatan Melalui LCD Nextion. Jurnal Teori Dan Aplikasi Fisika, 12(01), 103–112. https://doi.org/10.23960/jtaf.v12i1.14197

Triwerdani, A., Syaifudin, S., Utomo, B., & Basit, A. (2022). Mechanical Fetal Simulator for Fetal Doppler Testing. Journal of Electronics, Electromedical Engineering, and Medical Informatics, 4(2), 84–88. https://doi.org/10.35882/jeeemi.v4i2.5

Yulianti, T., Samsugi, S., Nugroho, P. A., & Anggono, H. (2021). Rancang Bangun Alat Pengusir Hama Babi Menggunakan Arduino Dengan Sensor Gerak. Jurnal Teknologi Dan Sistem Tertanam, 2(1), 21. https://doi.org/10.33365/jtst.v2i1.1032




DOI: https://doi.org/10.31764/justek.v8i2.31021

Refbacks

  • There are currently no refbacks.


JUSTEK : Jurnal Sains dan Teknologi sudah terindeks

    

EDITORIAL OFFICE: